State accedendo al sito dal Paese Stati Uniti.
Per il vostro Paese (Stati Uniti) è disponibile anche una versione dedicata del sito.

Passare a Stati Uniti

You need it, we have it. Noninvasive ventilation with the HAMILTON-C1

The HAMILTON-C1 is the complete solution for noninvasive ventilation (NIV), offering also all related consumables and accessories.

All‑in‑one. The complete system solution for noninvasive ventilation

The HAMILTON‑C1 ventilator provides high‑performance ventilation support ‑ from invasive and noninvasive modes through to high flow nasal cannula therapy (Also known as high flow oxygen therapy. This terminology can be used interchangeably with high flow nasal cannula therapy.A​) ‑ for neonates to adults.

Switch between invasive or noninvasive ventilation (NIV) and high flow nasal cannula therapy (HFNC) just by changing the ventilation mode and the patient interface. There is no need to change the device or even the breathing circuit.

This helps to save time, reduce your team's workload, the complexity of device training, and your consumables cost.

"" ""
Patient with NIV mask

For mask-wearers. High-performance noninvasive ventilation

The noninvasive ventilation modes on the HAMILTON-C1 deliver pressure‑supported, flow‑cycled spontaneous breaths (NIV and NIV‑ST mode) and pressure‑controlled, time‑cycled mandatory breaths (NIV‑ST).

With peak inspiratory flows of up to 260 l/min, the HAMILTON-C1 can meet your patient’s demands and guarantee optimal performance, even with large leaks.

Nurse and patient with the HAMILTON-C1 in HFNC mode

For O2 fanatics. High flow nasal cannula therapy

High flow nasal cannula therapy with flow rates of 2 to 100 l/min for adult patients is available as an option on the HAMILTON-C1.

In just a few steps, you can change the interface and use the same device and breathing circuit to accommodate your patient’s therapy needs.

Neonatal patient with NIV mask

For the little ones. Noninvasive modes for neonates

A variety of neonatal ventilation modes help support the baby according to its condition and needs.

With the nCPAP mode, the patient is supported with a continuous positive airway pressure. In our flow‑controlled devices, the desired CPAP value is set via the respiratory gas flow.

The LeakAssist function can be activated to compensate for any leakage that occurs, e.g., through the mouth or at the nose.

A predefined pressure can then be targeted with additional respiratory gas flow.

For neonatal patients, the HAMILTON-C1 offers flow rates of 2 to 30 l/min.

Ricky Williams

Cosa dicono i clienti

Il fatto di poter utilizzare l'HAMILTON-C1 anche per la CPAP e il trasporto lo rende un investimento conveniente per la struttura e riduce il carico di lavoro del personale.

Ricky Williams

RRT, Direttore reparto di Pneumologia
BridgePoint Continuing Care Hospital National Harborside, Washington DC, USA

Consumables for NIV

We offer the complete package of consumables for NIV and HFNC.

Request more information. Contact us

Book a free personal demonstration with one of our specialists to explore the benefits of our HAMILTON-C1 for noninvasive ventilation. They can guide you through the features and functionalities based on your specific needs.

Alternatively, you can schedule a callback, and our team will reach out to provide you with the necessary information and assistance.

Note

  • A. Nota anche come "terapia con ossigeno ad alto flusso". Questo termine e il termine "terapia ad alto flusso con cannula nasale" sono equivalenti.

Bibliografia